2024-08-16 16:30:30
Click:
Airtight water detection test bench-Tianjin Getes Testing Equipment Technology Development Co., Ltd.

Technical parameters
Control mode: computer automatic control
Test pressure: 3~600bar, pressure display accuracy 0.1bar; test pressure adjustable
Pressurization method: low pressure section/medium pressure section: 0.3~3MPa, low pressure pump first pressurizes and buffers, and then uses proportional valve to reduce pressure and inflate; high pressure section: 3~60MPa high pressure pump directly pressurizes
Test station: 1 station
Pressurization time: about 10min per piece
Pressure holding time: 1-9999S can be set
Leakage judgment: bubble recognition method (wet inspection) + pressure drop value per unit time (automatic detection)